Skip to content

Back to parent page - Aerosol nucleation


Clipping in aerosol nucleation for avoiding negative tracer concentration

  • If the maximum production of sulfuric aerosols exceeds the available sulfuric acid gas vapors, a reduction factor will be calculated:
\[ f_{correct} = \frac{\Delta qa_{SO_{4}}}{q_{H_{2}SO_{4}}} \]
  • If the \(J_{nuc}*f_{correct}\lt 10^{-12} /m^3/s\) then
\[J_{nuc} = 0.0\]

Otherwise,

\[J_{nuc} = J_{nuc}*f_{correct}\]
Back to top